Telefon +36-20-344-1787, vagy E-mail: rapaskft@rapas.hu

Ground resistance tester, Fuzrr ES3001

4-, 3- and 2-wire measurement. Ground resistance, soil resistivity and ground voltage measurement

ES3001 ground resistance tester, features

  • Earth resistance, soil specific resistance; ground voltage
  • Earth resistance: 0.00 Ω-30000 Ω
  • Soil resistivity: 0.00 Ωm-9999 kΩm
  • AC voltage measurement: 0.00V-600V
  • USB interface, + software
  • Measurement method: 4-, 3- and 2-wire measurement

The Fuzrr ES3001 portable digital ground resistance tester measures the resistance of the earthing system of electrical equipment and cables with high accuracy and resolution. The devices can be used to measure grounding or ground specific resistance in 2-, 3- and 4-wire measurement mode. The ground resistance measurement range is 0.01Ω ~ 30.00kΩ, the soil resistivity measurement range is 0.00Ωm~9999kΩm, so it is perfect for those who are looking for a reliable and easy-to-use device. The high noise level and the USB interface increase the ease of use of the Fuzrr ES3001 ground resistance tester, which allows you to download up to 500 groups of measured values. Whether it's a larger project or a smaller repair job, the ES3001 is the perfect tool for the job.

Műszaki adatok

Measuring range (automatic selection) Resolution Accuracy
Ground resistance measuerement
0.00~30.00Ω 0.01Ω ±2% MÉ ±5dgt 
30.0~300.0Ω 0.1Ω ±2% MÉ ±3dgt
300~3000Ω
3.00~30.00kΩ 10Ω
Soil specific resistance
0.00~99.99Ωm 0.01Ωm ρ=2πaR
100.0~999.9Ωm 0.1Ωm
1000~9999Ωm 1Ωm
10.00~99.99kΩm 10Ωm
100.0k~999.9kΩm 100Ωm
1000~9999kΩm 1kΩm
Ground voltage
0.00~100.0V AC 0.01V ±2% MÉ ±3dgt
  • Reference conditions: 23±5°C, <75% RH
  • Power supply: built-in DC 8.4 V lithium battery
  • Disruption voltage: <20V
  • Disturbing current: <2A
  • Distance of electrodes: adjustable between 1m and 100m, for R measurement: a>5d, for ρ measurement: a>20h
  • Auxiliary electrode resistance value: reference <100Ω, operating <5kΩ
  • Measurement methods:
    • Earth resistance: 3-wire measurement, simple 2-wire measurement, nominal current pole-changing method
    • Soil specific resistance: 4-wire method
    • Ground voltage: average value rectification (between S-ES bars)
  • Measuring frequency: 128Hz
  • Short circuit test current: >20mA (sine wave)
  • Open circuit test voltage: AC 28V max.
  • Backlight: changeable
  • Display: backlit 4-digit large LCD, display area: 108×65 mm
  • Indication of measurement in progress: LED flashes during measurement
  • Measurement time: ground voltage: approx. 3/s, grounding resistance, soil specific resistance: approx. 7 s
  • Ground voltage: ≤AC 100V, (the function cannot be used to measure mains voltage)
  • Data storage: 500 data groups
  • Automatically identify interference, "NOISE" message if Uz >5V
  • Auxiliary grounding test
  • Alarm if the measured value exceeds the set alarm value
  • Real-time display of battery charge
  • Automatic switch-off: approx. 15 minutes after idling
  • Dimensions (L, W, D): 277×227.5×153 mm
  • Weight:
    • Instrument: 2.4 kg (with battery)
    • Test cables: 1.3 kg:
    • Auxiliary earth electrodes: 0.9 kg (4 pcs)
  • Operating temperature: -10~40°C, <80% RH
  • Storage temperature: -20~60°C, <70% RH
  • Overload protection: AC 280V, 3 s between bars H-E and S-ES
  • Voltage Test: 3700 VACrms (between circuit and chassis)
  • EMC: IEC61326
  • Safety regulations:
    • IEC61010-1 (CAT III 300V, CAT IV 150V, pollution degree 2)
    • EC61010-031
    • IEC61557-1 (ground resistance)
    • IEC61557-5 (ground resistance)
    • JJG 366-2004

Scope of supply

100%
  • Measuring instrument
  • Carry bag:
  • Auxiliary electrodes: 4 pcs ∅10×200 mm
  • Normal measuring cable: 4 pcs. (15 m red; 10 m yellow; 10 m green; 15 m black)
  • Simple measuring cable 2 pcs.: (yellow, green: 1.6 meters each)
  • Built-in DC 8.4 V lithium battery
  • Battery charger
  • Software: CD
  • USB communication cable
  • User manual, warranty card